Stained water tanks

 

Corrosion protection of metal are constantly exposed to water and aqueous is a complex technical task that can only be solved with the use of high quality paints materials. Special responsibilities and complexity in terms of corrosion protection have storage tanks for drinking water. International PC Company has developed and certified a number of epoxy and epoxy-phenolic material for this purpose. Below are some coating and coating systems.

 

1. Coating systems for storage tank for potable cold water, solt solutions; tanks and metal structures, buried in the ground.

 

Product name
Discriptions
Dry residue
%
Dry film thickness, micron
Theoretical coverage
 m2/l
The interval coloring
MinMax 25°C
Versatile epoxy coating
82
125
6,56
10 hours- 4 weeks
Versatile epoxy coating
82
125
6,56
10 hours - 4 weeks
Total
 
 
250
 
 

 

2. The outer surfaces of containers and tanks 

Product name
Discriptions
Dry residue
%
Dry film thickness, micron
Theoretical coverage
 m2/l
The interval coloring
MinMax 15°C
Versatile epoxy coating
82
100
8,2
10 hours - 4 weeks
External polyurithane coating
57
50
11,40
> 10 hours
Total
 
 
150